UV26DCMed UV Adhesive
UV26DCMed
One component, dual cure system with UV and heat curing mechanisms for bonding and sealing, passes ISO 10993-5 for cytotoxicity
Dielectric Constant
3.85
Glass Transition Temperature (Tg)
160-170°C
  • ISO 10993-5 for Cytotoxicity
  • RoHS Compliant
  • Bonding
  • Sealing
Part A: 500-3,500 cps, Part B: Cures at 110-125°C for 60-90 minutes, followed by a post cure at 120-150°C for 1-2 hours 80-90 Shore D -60°F to +500°F /tds/uv26dcmed
Master Bond UV26SP Epoxy System
UV26SP
One part, low viscosity UV curable system featuring high temperature resistance for bonding, sealing and coating
Glass Transition Temperature (Tg)
160 to 170°C
Refractive Index
1.55
  • NASA Low Outgassing
  • RoHS Compliant
  • Bonding
  • Sealing
  • Coating
  • Gap Filling
250-1,500 cps UV light 320-365 nm for 10-20 seconds 80-90 Shore D -60°F to +500°F /tds/uv26sp
X18 One Component Elastomeric System
X18
One component primer/adhesive for polyolefins
Glass Transition Temperature (Tg)
25-30°C
Volume Resistivity
>10¹⁴ ohm-cm
  • RoHS Compliant
  • Bonding
  • Priming
<2,500 cps 75°F for 12-24 hours; 150°F for 1-2 hours -60°F to +200°F /tds/x18
X18Med One Component Primer/Adhesive
X18Med
One component primer/adhesive for polyolefins, passes ISO 10993-5 test
Glass Transition Temperature (Tg)
25-30°C
Volume Resistivity
>10¹⁴ ohm-cm
  • ISO 10993-5 for Cytotoxicity
  • RoHS Compliant
  • Bonding
  • Priming
<2,500 cps 30-45 minutes with full cures in 12-24 hours; if cured at 150°F the curing time will be 1-2 hours -60°F to +200°F /tds/x18med
X21 Elastomer Based One Component Adhesive
X21
One component primer/adhesive for polyolefins
Glass Transition Temperature (Tg)
25-30°C
Volume Resistivity
>10¹⁴ ohm-cm
  • RoHS Compliant
  • Bonding
  • Priming
<250 cps 12-24 hours at 75°F; 1-2 hours at 150°F -60°F to +200°F /tds/x21
X21Med One Component Elastomeric System
X21Med
One component primer/adhesive for polyolefins, passes ISO 10993-5 test
Glass Transition Temperature (Tg)
25-30°C
Volume Resistivity
>10¹⁴ ohm-cm
  • ISO 10993-5 for Cytotoxicity
  • RoHS Compliant
  • Bonding
  • Priming
30-250 cps 12-24 hours at 75°F, 1-2 hours at 150°F -60°F to +200°F /tds/x21med