One Part, Fast Curing Epoxy Meets NASA Low Outgassing Specifications

Master Bond EP3HT-LO is a single component, non-premixed & frozen, heat cured epoxy, with an unlimited working life at room temperature. This system passes ASTM E595 tests for NASA low outgassing, making it well suited for use in the aerospace, electronic, microelectronic and optical industries.

EP3HT-LO features a good strength profile, with a lap shear strength of 1,600-1,800 psi, a tensile strength of 5,000-6,000 psi and a tensile modulus of 250,000-300,000 psi. It withstands 1000 hours of 85°C/85% RH exposure. This formulation offers reliable electrical insulation properties with a dielectric constant of 3.9 at 60 Hz and a volume resistivity of greater than 1014 ohm-cm, at room temperature. EP3HT-LO withstands a variety of chemicals such as water, oils, fuels, acids and bases. This high temperature resistant system is serviceable from -60°F to +400°F (-51°C to 204°C).

As a one-part compound, EP3HT-LO offers convenient handling and processing. It cures with heat, quickly polymerizing in as little as 5-10 minutes at 300°F (~ 150°C). This epoxy bonds well to metals, glass, composites, ceramics and many plastics. EP3HT-LO is available for use in ½ pints, pints, quarts, gallons and syringes. It has a shelf life of 6 months at ambient temperatures in original, unopened containers.

Master Bond’s Epoxy Compatibility with STERIS’s Vaporized Hydrogen Peroxide Sterilization Process

Master Bond and STERIS collaborated in research to determine the compatibility of Master Bond’s specialty epoxies with Vaporized Hydrogen Peroxide (VHP™) using V-PRO® s2 Low Temperature Sterilization System. This study was recently published in a peer-reviewed journal Polymer-Plastics Technology and Materials.

As medical devices have evolved through technological advancements, they have become more complex in both their design and materials of construction. Medical grade biocompatible epoxies are widely used in reusable medical devices. Choosing an epoxy that maintains its performance characteristics when subjected to repeated sterilization throughout the reusable medical device’s lifespan is a known challenge for medical device manufacturers. This study evaluated the material compatibility of seven cured two part and one part epoxies used in medical devices following exposure to 100 cycles in a low temperature vaporized hydrogen peroxide sterilizer.

Six of the seven epoxies tested were found to be compatible with vaporized hydrogen peroxide sterilization based on qualitative, hardness and weight measurements conducted post exposure to 100 VHP cycles. The epoxies deemed to be compatible displayed no visual signs of physical defects, minimal reduction in hardness (≤2%) and total weight gain (≤2.9%). This study highlights the importance of conducting material compatibility studies, and continued collaborations (among medical device manufacturers, sterilizer manufacturers and epoxy manufacturers) during the early stages of medical device development to ensure a successful reusable medical device that will withstand repeated sterilization

Key Findings from the Study about Master Bond Medical Adhesive Systems

The Master Bond EP42HT-2Med, EP42HT-4AOMed Black, EP62-1HTMed, EP41S-5Med, EP4CL-80Med and UV10TKMed epoxies are compatible with low temperature vaporized hydrogen peroxide, as they maintained their surface texture, exhibited less than 2% change in hardness, and displayed less than a 2.5% weight gain post exposure to 100 VHP cycles.

To read the experiment and results in its entirety please go to https://www.tandfonline.com/doi/full/10.1080/25740881.2024.2376209 or contact technical support to discuss your application.

Rectifiers

Potting, coating and encapsulation polymers for rectifiersThese vital electronic devices are employed to convert alternating current (AC) to direct current (DC).

Undefined

Toughened, One Component Epoxy Features High Glass Transition Temperature

Master Bond Supreme 17HTND-2 is a toughened epoxy system for bonding and sealing applications. It is a true one component system, not premixed and frozen, with an unlimited working life at room temperature. Supreme 17HTND-2 is thermally stable, featuring a high glass transition temperature (Tg) of 410°F (210°C). It also meets NASA low outgassing specifications per ASTM E595 testing.

Supreme 17HTND-2 has reliable electrical insulation properties with a volume resistivity exceeding 1015 ohm-cm at 75°F. It possesses high bond strength properties with a lap shear strength of 1,900-2,100 psi and a tensile strength of 7,000-8,000 psi. It is designed to withstand thermal cycling and offers a wide service temperature range from -100°F to +550°F (-73°C to 288°C). Along with its simple handling properties, it has a paste consistency and is completely non-drip, making it ideal for applications where no flow is critical.

Supreme 17HTND-2 cures at elevated temperatures with cure schedule options including 300°F for 4-6 hours or 350°F for 2-4 hours. An optimal cure schedule is at 300°F for 4-6 hours, followed by a post cure at 350°F for 8-12 hours. It bonds well to a wide variety of substrates including metal, ceramics, composites and several plastics. Black in color, it is available in standard packaging of jars and cans, ranging from ½ pint to gallon containers.

One Part, Toughened Epoxy for Dam-and-Fill Encapsulation

Master Bond Supreme 3DM-85 is a no mix, non-solvent based, one component epoxy. This thixotropic paste material was formulated to serve as the damming compound in dam-and-fill encapsulation applications. It can also be utilized for bonding and sealing, especially where no flow is needed since the material cures in place and will not run or slump. The compound requires a relatively low heat cure of 85°C for 2-3 hours, is thermally conductive and electrically non-conductive.

“Supreme 3DM-85 is designed for heat sensitive components that cannot withstand high temperatures for curing. The fact that it is not premixed and frozen gives it an advantage in production situations where freezer storage may not be practical. Also, there are no special shipping requirements,” says Senior Product Engineer Rohit Ramnath. As a toughened system, Supreme 3DM-85 resists rigorous thermal cycling. It is a reliable electrical insulator and features a thermal conductivity of 5-10 BTU•in/ft2•hr•°F [0.72-1.44 W/(m·K)]. It plays an important role in facilitating effective heat dissipation and preventing overheating, especially in densely packed electronic assemblies. The epoxy maintains a Shore D hardness of 75-85, offers excellent damp heat resistance and has a good physical strength profile.

Supreme 3DM-85 forms strong bonds with an extensive range of substrates commonly found in electronics and semiconductors. Substrates include metals, composites, ceramics, silicon, and a wide array of plastics. As a single part system, it is easy to handle and offers unlimited working life at room temperature. It is opaque black in color and can be applied manually or automatically. Serviceable from -100°F to +350°F [-73°C to +177°C], Supreme 3DM-85 is available for use in syringes and jars.

Thixotropic Epoxy Features Low Coefficient of Thermal Expansion

Master Bond EP5LTE-100 is a one part, non-premixed and frozen epoxy with a very low coefficient of thermal expansion (CTE), high glass transition temperature (Tg), and extremely high modulus. It has a thixotropic paste consistency making it ideal for bonding, sealing and gap filling applications. These properties are especially useful for opto-electronics or applications needing high dimensional stability and good heat resistance.

EP5LTE-100 passes NASA low outgassing specifications. It provides a tensile modulus that exceeds 1 million psi at room temperature. Minimal shrinkage upon cure combined with a low CTE of 8-12 x 10-6 in/in/°C enables precise alignment for bonding dissimilar substrates with low coefficients of thermal expansion. With a Tg between 120-125°C, and a service temperature range from -60°C to +175°C, this epoxy is effective in high temperature environments. It is a reliable electrical insulator featuring a volume resistivity of more than 1014 ohm-cm.

EP5LTE-100 bonds well to a wide variety of substrates including metals, glass, composites, ceramics and many plastics. It has good resistance to water and damp heat. The compound has an unlimited working life at room temperature and requires a heat cure at 100°C for 90-120 minutes. Optimum properties are obtained by post curing for 2-3 hours at 100-125°C. The epoxy is available in syringes, jars, and cans.

Die Attach Epoxy Featuring High Tg Meets NASA Low Outgassing Requirements

Master Bond EP17HTDA-2 is a one component epoxy that can be used for bonding, sealing and die attachment. It is not premixed and frozen, and cures with heat. This dimensionally stable system features excellent mechanical properties with both a high modulus and die shear strength. It transfers heat and resists thermo-mechanical stresses effectively.

EP17HTDA-2 has exceptional temperature resistance with a service temperature range of -80°F to +600°F [-62°C to +316°C] and a Tg of 185-190°C. This compound has a thermal conductivity of 9-10 BTU•in/ft2•hr•°F [1.30-1.44 W/(m·K)], a low coefficient of thermal expansion, and is also electrically insulative with a volume resistivity greater than 1015 ohm-cm. It withstands a variety of chemicals including acids, bases, salts, fuels, oils, water and many solvents.

As a one part system, EP17HTDA-2 does not require any mixing and is curable in the temperature range of 300-350°F for around 4-5 hours. To optimize properties, a post cure of 2-3 hours at 400°F is recommended. It bonds well to a wide variety of substrates, such as metals, ceramics, plastics and composites. Upon curing, it delivers a tensile modulus exceeding 1,100,000 psi and a die shear strength of 20-23 kg-f at room temperature (2 x 2 mm [80 x 80 mil]). It also has minimal shrinkage upon curing.

While EP17HTDA-2 is well suited for electronic and related applications, it can also be used in vacuum situations as it passes NASA low outgassing testing. It is a thixotropic paste, yet is available in 10 cc and 30 cc syringes for automated dispensing, and has a shelf life of 3-6 months when stored at 40-50°F.

Biocompatibility Tests for Adhesives

What biocompatibility tests can be performed on an adhesive to be considered for use in a medical device application?

Oscillators

Adhesive, sealant and coating compounds for oscillatorsMaster Bond adhesives, sealants, coatings, and potting compounds are commonly employed in numerous types of oscillators for multiple applications.

Undefined

Industrial Automation Equipment

Adhesives, Sealants and Coatings for Industrial Automation EquipmentMaster Bond is a preeminent supplier of high performance adhesives, sealants, coatings, and potting/encapsulation compounds used for assembling industrial automation equipment.

Undefined

Pages